Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros








Intervalo de ano de publicação
1.
Braz. j. biol ; 842024.
Artigo em Inglês | LILACS-Express | LILACS, VETINDEX | ID: biblio-1469372

RESUMO

Abstract Nanoparticles (NPs) are insoluble particles with a diameter of fewer than 100 nanometers. Two main methods have been utilized in orthodontic therapy to avoid microbial adherence or enamel demineralization. Certain NPs are included in orthodontic adhesives or acrylic resins (fluorohydroxyapatite, fluorapatite, hydroxyapatite, SiO2, TiO2, silver, nanofillers), and NPs (i.e., a thin layer of nitrogen-doped TiO2 on the bracket surfaces) are coated on the surfaces of orthodontic equipment. Although using NPs in orthodontics may open up modern facilities, prior research looked at antibacterial or physical characteristics for a limited period of time, ranging from one day to several weeks, and the limits of in vitro studies must be understood. The long-term effectiveness of nanotechnology-based orthodontic materials has not yet been conclusively confirmed and needs further study, as well as potential safety concerns (toxic effects) associated with NP size.


Resumo Nanopartículas (NPs) são partículas insolúveis com diâmetro inferior a 100 nanômetros. Dois métodos principais têm sido utilizados na terapia ortodôntica para evitar a aderência microbiana ou a desmineralização do esmalte: NPs são incluídas em adesivos ortodônticos ou resinas acrílicas (fluoro-hidroxiapatita, fluorapatita, hidroxiapatita, SiO2, TiO2, prata, nanopreenchimentos) e NPs são revestidas nas superfícies de equipamentos ortodônticos, ou seja, uma camada fina de TiO2 dopado com nitrogênio nas superfícies do braquete. Embora o uso de NPs em ortodontia possa tornar acessível modernos recursos, pesquisas anteriores analisaram as características antibacterianas ou físicas por um período limitado de tempo, variando de 24 horas a várias semanas, por isso devem ser compreendidos os limites dos estudos in vitro. A eficácia de longo prazo de materiais ortodônticos com base em nanotecnologia ainda não foi confirmada de forma conclusiva, o que exige mais estudos, bem como potenciais preocupações de segurança (efeitos tóxicos) associadas ao tamanho da NP.

2.
Braz. j. biol ; 84: e257070, 2024. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-1360228

RESUMO

Nanoparticles (NPs) are insoluble particles with a diameter of fewer than 100 nanometers. Two main methods have been utilized in orthodontic therapy to avoid microbial adherence or enamel demineralization. Certain NPs are included in orthodontic adhesives or acrylic resins (fluorohydroxyapatite, fluorapatite, hydroxyapatite, SiO2, TiO2, silver, nanofillers), and NPs (i.e., a thin layer of nitrogen-doped TiO2 on the bracket surfaces) are coated on the surfaces of orthodontic equipment. Although using NPs in orthodontics may open up modern facilities, prior research looked at antibacterial or physical characteristics for a limited period of time, ranging from one day to several weeks, and the limits of in vitro studies must be understood. The long-term effectiveness of nanotechnology-based orthodontic materials has not yet been conclusively confirmed and needs further study, as well as potential safety concerns (toxic effects) associated with NP size.


Nanopartículas (NPs) são partículas insolúveis com diâmetro inferior a 100 nanômetros. Dois métodos principais têm sido utilizados na terapia ortodôntica para evitar a aderência microbiana ou a desmineralização do esmalte: NPs são incluídas em adesivos ortodônticos ou resinas acrílicas (fluoro-hidroxiapatita, fluorapatita, hidroxiapatita, SiO2, TiO2, prata, nanopreenchimentos) e NPs são revestidas nas superfícies de equipamentos ortodônticos, ou seja, uma camada fina de TiO2 dopado com nitrogênio nas superfícies do braquete. Embora o uso de NPs em ortodontia possa tornar acessível modernos recursos, pesquisas anteriores analisaram as características antibacterianas ou físicas por um período limitado de tempo, variando de 24 horas a várias semanas, por isso devem ser compreendidos os limites dos estudos in vitro. A eficácia de longo prazo de materiais ortodônticos com base em nanotecnologia ainda não foi confirmada de forma conclusiva, o que exige mais estudos, bem como potenciais preocupações de segurança (efeitos tóxicos) associadas ao tamanho da NP.


Assuntos
Ortodontia , Desmineralização , Esmalte Dentário , Nanopartículas , Anti-Infecciosos
3.
Arch Razi Inst ; 78(1): 115-123, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-37312694

RESUMO

Scientists have been paying attention to the life-giving properties of medicinal plants for many years. Among these plants is the eucalyptus plant. This plant has various compounds such as cineole and terpenes. It also contains compounds such as flavonoids, aliphatic aldehydes, sesquiterpene, quinotanen, catechins, salts, and vitamins. In the present study, the hydroalcoholic extract of Eucalyptus leaves with concentrations of 175, 350, and 700 mg/kg body weight, and spermatogenesis were studied in 40 adult Wistar rats in five groups of eight. Adult male mice received the extract at the above concentrations by gavage for 28 days. Control mice received only solvent and water, while control mice received no substance other than municipal tap water and normal food. After the last administration of the drug, the animals were weighed and anesthetized, and then blood samples were taken from their hearts. Concentrations of LH, FSH, and testosterone were measured by an ELISA kit. The results showed that body weight and testis, seminiferous tube diameter, Leydig cell diameter, epithelium thickness, number of Leydig cells, spermatogonium, spermatocytes, spermatids, sperm, and testosterone concentration increased significantly with the group. But no significant difference was observed in the concentration of FSH and LH hormones or the number of Sertoli cells. Therefore, it can be concluded that eucalyptus leaf extract may increase the proliferation of sex cells in the seminiferous tubules of rats.


Assuntos
Eucalyptus , Testosterona , Masculino , Camundongos , Ratos , Animais , Ratos Wistar , Sementes , Espermatozoides , Peso Corporal , Extratos Vegetais/farmacologia , Hormônio Foliculoestimulante
4.
Braz J Biol ; 84: e257021, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35703637

RESUMO

The aim of this paper is to better understand the dynamics of crystallogenic and starting activity in biological fluids of patients throughout surgery and the late postoperative phase in alveococcosis. Samples of saliva from 22 individuals with alveococcosis were included in the research. Biological fluid samples were taken at the time of admission and before the patient was discharged. Following that, slides were made utilizing the teziocrystalloscopy method, which incorporates the investigation of the crystal forming activity of mixed saliva with its starting characteristics using a 0.9 percent sodium chloride solution as the foundation ingredient. Using our own set of criteria, we evaluated the outcomes of crystalloscopic and tezigraphic experiments. Specrophotometric examination of tezigraphic and crystalloscopic facies was done using a PowerWave XS microplate spectrophotometer at wavelengths of 400, 350, and 300 nm to augment the results from ocular morphometry of dried saliva micro slides. Surgical therapy results in a partial normalization of physical and chemical parameters, as well as the composition of the patient's biological fluids after the patient is discharged from the hospital.


Assuntos
Equinococose , Humanos , Saliva
5.
Braz J Biol ; 84: e257070, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35195179

RESUMO

Nanoparticles (NPs) are insoluble particles with a diameter of fewer than 100 nanometers. Two main methods have been utilized in orthodontic therapy to avoid microbial adherence or enamel demineralization. Certain NPs are included in orthodontic adhesives or acrylic resins (fluorohydroxyapatite, fluorapatite, hydroxyapatite, SiO2, TiO2, silver, nanofillers), and NPs (i.e., a thin layer of nitrogen-doped TiO2 on the bracket surfaces) are coated on the surfaces of orthodontic equipment. Although using NPs in orthodontics may open up modern facilities, prior research looked at antibacterial or physical characteristics for a limited period of time, ranging from one day to several weeks, and the limits of in vitro studies must be understood. The long-term effectiveness of nanotechnology-based orthodontic materials has not yet been conclusively confirmed and needs further study, as well as potential safety concerns (toxic effects) associated with NP size.


Assuntos
Braquetes Ortodônticos , Ortodontia , Antibacterianos , Braquetes Ortodônticos/microbiologia , Dióxido de Silício , Titânio
6.
Acta Med Indones ; 37(3): 149-56, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16135879

RESUMO

AIM: to investigate association between growth disorders in pre and post natal period and abnormal lipid profile in adolescents aged 12 -15 years old in Tanjungsari population. METHODS: a cohort study was conducted in 3350 children who were born in 1988-1990 in Tanjungsari Subdistrict, Sumedang, West Java. A complete anthropometric data since their birth were collected from October 2002-February 2003. INCLUSION CRITERIA: Children who had birth weight in the range of +/- 3 of standard deviation (SD). Post natal growth disorder based on Z score of height according to age group and height changes at the age of 0-12 months and 12-36 months. SGA criteria were determined based on cross tabulation between weight and birth length at birth. Study subjects were divided into control group, groups of pre natal, post natal and pre-postnatal growth disorder. All subjects were checked for lipid profiles. Statistical calculation used analysis of variance, t test and logistic regression. 312 subjects were included in this study, 73 were in control group, 90 subjects in postnatal, 96 subjects were in pre natal and 53 subjects were in pre-post natal growth disorder group. RESULTS: this study has not shown significant difference in risk factor of having abnormal lipid profile between normal control group and growth disorder group except for those in prenatal growth disorder group with RR = 2.375 (p = 0.014). CONCLUSION: the post natal growth disorder had not influenced lipid profile in adolescents with SGA. Recent BMI was an additional risk factor for pre-post natal growth disorder group.


Assuntos
Desenvolvimento Fetal , Transtornos do Crescimento/complicações , Lipídeos/sangue , Adolescente , Peso ao Nascer , Índice de Massa Corporal , Criança , Desenvolvimento Infantil , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Indonésia , Lactente , Recém-Nascido , Masculino , Fatores de Risco
7.
Knee Surg Sports Traumatol Arthrosc ; 13(4): 248-55, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15690197

RESUMO

Multiple techniques for anterior cruciate ligament (ACL) reconstruction are currently available, most of which use hardware or resorbable material for fixation of the graft inside or outside the bony tunnels. In this study, the long-term results of 95 patients at a mean follow-up of 10.7 years were assessed. The ACL was reconstructed using a patellar tendon autograft with a press-fit fixation. Between 1987 and 1991, 159 patients were operated by the senior author (PH), 95 could be seen for follow-up. Evaluation included detailed history, physical examination, functional knee ligament testing, KT-1000 arthrometer testing, the IKDC standard evaluation form, Lysholm, Flandry, and Tegner scoring systems. Radiographs were obtained preoperatively and at follow-up to assess the grade of osteoarthritis. Subjectively, none of the patients that were seen for follow-up complained of instability. Numbness of the skin was reported by 54% of the patients and pain during knee walking was described as mild in 25% and severe in 2%. The mean Flandry score was 243 (max: 280). The mean Lysholm score was 93.2 at follow-up and the Tegner activity level was 6.8 preinjury and 6.0 postoperatively. The average KT-1000 side-to-side difference was 1.8 mm on a manual maximum pull. The IKDC knee scoring revealed 84% of the patients with normal (A) or nearly normal (B) knee joints, 15% were (C), 1% was (D). Radiographically, joint space narrowing was found in 19%, 15%, and 25% for the patello-femoral, medial, and lateral compartments, respectively. Meniscus surgery was a determining factor. This study presents long-term clinical data on a press-fit fixation for ACL reconstruction. Results were excellent and good in more then 80% of the followed patients. The advantages of the press-fit fixation are direct bone-to-bone healing of the graft, decreased donor site morbidity, cost-effectiveness and ease for revision surgery.


Assuntos
Ligamento Cruzado Anterior/cirurgia , Traumatismos em Atletas/cirurgia , Traumatismos do Joelho/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Tendões/transplante , Adulto , Idoso , Lesões do Ligamento Cruzado Anterior , Artroscopia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Patela , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Transplante Autólogo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA